Hydrogen fuel cell bipolar plate,membrane electrode assembly automatic testing equipment is developed by Jinchen Stock for hydrogen fuel cell bipolar plate,membrane electrode assembly size,appearance and airtight automatic testing platform.
Hydrogen fuel cell bipolar plate and membrane electrode assembly automatic testing equipment includes automatic product feeding,labeling,marking,size testing,appearance testing,airtight testing,classification,packaging,electrical control system,data acquisition system and other functional modules,compatible with a variety ofproduct models colinear production,model automatic identification and switching,production tasks are automatically sent to the equipment from MES.Production quality data is automatically uploaded for analysis and processing,and real-time monitoring of equipment status integrates a number of intelligent manufacturing core technologies such as digital manufacturing,Internet of Things,and intelligent control
Technical Parameters | |||
---|---|---|---|
Product size | Customizable | Gas filling pressure | 2~200Kpa |
Seal pressing pressure | 0~5t | Leakdetecting seal pressure | 0~300Kpa |
Leak detection mode | Pressure differential type/flow type | Flow range | 0~200sccm |
Detection accuracy | ±1.5%F.S | Bipolar plate leak detection standard | ≤0.2ml/min |
Membrane electrode assembly leak detection standard | <17uL/min/c㎡ | Appearance detection | Pits,cracks,warps,imperfections,stains,burrs,etc |
Dimensional detection accuracy | ±0.01mm | Customization or not | Available |
Detecting gas fluid | Air/Nitrogen |